Protection: Over load, over voltage, short circuit
Model
Specification
S-50-5
S-50-12
S-50-15
S-50-24
DC output voltage
5V
12V
15V
24V
Output voltage error (Note2)
± 2%
± 1%
± 1%
± 1%
Rated output current
10A
4.2A
3.4A
2.1A
Output current rage
0-10A
0-4.2A
0-3.4A
0-2.1A
Wave and noise(Note3)
75mVp-p
100mVp-p
100mVp-p
100mVp-p
Inlet stability(Note4)
± 0.5%
± 0.5%
± 0.5%
± 0.5%
Load stability(Note5)
± 1%
± 0.5%
± 0.5%
± 0.5%
DC output power
50W
50.4W
50.4W
50.4W
Efficiency
71%
78%
78%
82%
Adjustable range for DC voltage
± 10, -5%
± 10%
± 10%
± 10%
AC input voltage range
85∼ 132VAC/170∼ 264VACselected by switch
Input current
1.3A/115V 0.65A/230V
AC impulse current
Cold-start current 18A/115V 36A/230V
Leakage current
< 0.5mA/240VAC
Overload protection
105%∼ 150%TypeTOLDBACK Reset: auto recovery
Over-voltage protection
High-temperature protection
Temperature coefficient
± 0.03%(0∼ 50)
Setup rise hold up time
200ms, 100ms, 30ms
Vibration
10∼ 500Hz, 2.10min. /1cycle, Period for 60min, Each axes
Withstand voltage
Input and output interval1.5KVAC, Input and enclosure1.5KVAC, Output and enclosure0.5KVAC
Isolation resistance
Input and output interval, Input and enclosure, Output and enclosure0500VAC/100M Ohms
Working temperature and humidity
-10∼ +60, 20%∼ 90%RH
Store temperature and humidity
-20∼ +85, 10%∼ 95RH
Overall dimension
159*97*38mm
Weight
0.5Kgs
Safety standards
Meet UL1012
EMC standards
Note: 1. The testing condition for the parameter above is: 230VAC input, rated load, 25 70%Rh, Humidity
2. Error, include the setting error, line stability and load stability. (Note: 5)
3. Wave test: adoptingA12double wire for 20MHz, and 0.1uF& uF capacitor short-circuit for interrupting
4. Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.
5. Load stability test: The load is from 0% to 100%, others 60%.
6. C2311must be knocked down.